Alco sensor fst calibration manual

Alcosensor fst police breathalyzer with lcd screen and short. X alco sensor iii enhanced with serial numbers above 1,200,000 x. Dot evidential breath testing instruments kahntact medical. User manuals, guides and specifications for your intoximeters alcosensor fst kitchen appliances, test equipment. Alco sensor fst alco sensor fst 200k 6 lpm regulator intoximeters c tank multi button calibration using 6 lpm pbt should auto sample in both acccal fst 200k has additional memory approved in 20032015. During testing, the unit compares users breath samples to these baseline values. Intoximeters alcosensor fst operators manual pdf download.

Complete the alco sensor iii pbt certification record. Approved in most states as a pbt preliminary breath tester, for law enforcement. Alcosensor iv with memory with dp impact printer dot. Leverpush down to lock into e06 exceeded sample attempt allotment place. Familiarize yourself with the operating instructions for the alco sensor fst by. Alco sensor fst calibration adjustment instructions. When the alcosensor iv flashes test, depress the valve on mini alcohol can for 4 seconds.

Accuracy check alco sensor fst record keeping to demonstrate compliance with your programs qap quality assurance plan it is best to keep a record or a calibration log for each device used for testing. Intoximeters alcosensor fst manuals and user guides. For maximum accuracy, calibration of the unit should be verified every 6 to 12 months. View online operators manual for intoximeters alcosensor fst test equipment or simply click download button to examine the intoximeters alcosensor fst guidelines offline on your desktop or. Alcosensor fst operator manual and certificates of analysis. Intoximeter alcosensor fst breathalyser with printer its test kits. Alcosensor fst calibration procedure 1 attach a new mouthpiece then press and hold the off button while simultaneously pressing the on button. If using a truecal device, the expected value of the standard will be displayed. The alco sensor fst was designed with operator safety in mind.

Hold down for several seconds if back lighting is preferred. The intoximeters alcosensor iii is a handheld, 3 digit display, portable, preliminary screener instrument intended for use whenever a rapid onthespot breath alcohol measurement is required. The instrument is also designed to offer a simple passive testing procedure for quick screening of a large number of subjects and the capability of measuring the headspace over a solution to identify alcohol in a suspected open container. Alco sensor fst the operator introduces the calibration gas standard into the fst with the calibration procedure described in z asfst operators manual call r for technical assistance supplies repair information intoximeters inc. Once the data is downloaded, reporting tools included within the software package allow the data. Programs which use the alco sensor iv very frequently, or who must meet rigorous quality control regulations, may require a more frequent accuracy check interval. The alco sensor is an alcohol screening device approved for use by the attorney general of canada.

On the 3rd second of the 4 second count, press the on button. This product works flawlessly every time, and the ease of the use of it is fantastic. The alcosensor fst was approved for use as a screening device in 2012. Learn how to capture a breath sample on the intoximeters alcosensor fst. We have led the breath alcohol testing industry for over 60 years. Because the alco sensor fst is a handheld device, it is susceptible to damage from dropping, transportation, travel, and frequent handling.

Utilising one of the highest quality electrochemical fuel cell select sensors available, manufactured to exacting specifications for accuracy, repeatability and long life. These sensors are far more prone to contamination and interference from substances other than breath alcohol. View online or download intoximeters alco sensor fst operators manual. Transmitters of the fst series are equipped with a 5pin keyed test connector that permits reading the signals without interrupting the operation of the transmitter. Page 1 alcosensor fst alcosensor fst basic operation checklist quick reference status messages 1. Learn how to capture a breath sample on the intoximeters alco sensor fst.

The manufacturer admits that the accuracy of a subject test result is dependent upon a properly calibrated instrument, but it fails to define what the accuracy or calibration requirements should be for a properly working device. The alcosensor fst breathalyzer from intoximeters is trusted by law enforcement and corrections agencies worldwide for the following reasons. The log should contain the results of all accuracy checks and calibrations for each instrument. Obtain certified dry gas alcohol standards for which the reference value is known and an intox regulator is attached. Both the able thermal printer and the star slip printer can interface with the alco sensor iv with memory. Alco sensor fst alco sensor fst 200k 6 lpm regulator intoximeters c tank multi button calibration using 6 lpm pbt should auto sample in both acccal fst. Impaired driving is the leading cause of criminal death in canada. The alco sensor iv is designed to automatically capture a small portion of deep lung air as the breath passes through the instrument and deliver it to the fuelcell sensor for measurement. Alcosensor fst operators manual province of british columbia. In our library of records we have calibration documents and service records for many of the alco sensor fst units currently in service. Alcosensor fst operator manual and certificates of. The calibration procedures below are designed to help you ensure precise and accurate test results.

Intoximeters alcosensor fst manuals and user guides, kitchen. Neither this course nor the exam is based on that manual. Page 2 this manual is not intended to supersede the guidelines set forth by the regulatory authority. Attach mouthpiece insert closed end of mouthpiece into end of channel, single hole facing up. Alco sensor fst approved screening device acumen law. Intoximeters alcosensor fst test equipment operators manual. Accuracy check and calibration procedure for the alco.

This video shows stepbystep instructions for performing a calibration adjustment on the alco sensor fst breath alcohol device. Calibration and calibration check modes automatic sampling, handheld passive screening device calibration mode access via fst view compatible with both wet. View and download intoximeters alco sensor fst operators manual online. Over this period of time, all asds provided results within the acceptable range of 95 to 105 milligrams of alcohol in 100 millilitres of blood mg% when challenged with an alcohol standard with a target result of 100 mg%. How to conduct a calibration on the alcosensor fst youtube. Sensor uses a genuine, evidential quality intoximeters electrochemical fuel cell sensor that is highly specific for alcohol in the human breath calibration and calibration check modes automatic sampling, handheld passive screening device calibration mode access via fst view compatible with both wet bath and dry gas alcohol standards. Programs that use the alcosensor fst very frequently, or that must meet rigorous quality control regulations, may require a more frequent accuracy check interval. Kentucky revised statues, alco sensor iii, alco sensor fst and the sd2 manuals completed by. The approved screening device commonly used at this time in bc is the alco sensor fst, a device produced by intoximeters of saint louis. Many handheld breath analyzers sold to consumers use a silicon oxide sensor also called a semiconductor sensor to determine the blood alcohol concentration.

Database contains 4 intoximeters alcosensor fst manuals available for free online viewing or downloading in pdf. Alcosensor calibration information instructional videos al. Asd approved screening device roadside breath tester bc. The intoximeters alcosensor fst fst is a pocketsized, handheld breath alcohol tester with a symmetric design and rearfacing display, which allows an operator to remain aware of the subject and surroundings. Insert the small plastic tubing on the valve into the end of the mouthpiece that is already in the alcosensor f st. The alco sensor fst s symmetric design allows the operator to remain in control of the subject, view the instrument display, monitor the surrounding environment and divert the subjects breath away from the operator during the sample collection process. Page 1 alco sensor fst operator manual intoximeters, inc.

Below are basic calibration instructions for the intoximeters alco sensor fst breath testing instrument. Alco sensor iv with memory and slip printer the alco sensor iv with memory and slip printer is intended for regulated and nonregulated workplace testing programs that are stationary. The alco sensor fst as fst provides precise, accurate, repeatable results on direct breath sample testing. It has a double pump system and a 1inch sensor to provide highly accurate results. This manual covers the operating information and procedures for the alcosensor fst. It is important to press the manual button while the gas is still flowing. Alco sensor fst calibration procedure 1 attach a new mouthpiece then press and hold the off button while simultaneously pressing the on button. Powerpoint, student manual, lab work sheet, cups, mouthwash, sd2, alco sensor iii and fst, appropriate mouth pieces for each instrument. Initial trainingintoximeters alcosensor fst asfst attorney.

Calibration calibration of the alcohawk pt500 occurs during manufacturing using advanced alcohol simulation equipment. The alco sensor fst is replacing the alco sensor ii as the preferred astd in the charlotte area. A disposable mouthpiece, two aa batteries, and a calibration standard are the only items necessary to keep the alco sensor. Alco sensor v xl evidentialgrade, handheld unit with a patented rearfacing display designed for operator safety intoximeters instruments have been proven time and time again to be the most accurate on the market.

Alcosensor fst police breathalyzer with lcd screen and. Alcosensor fst breathalyzer for law enforcement accurate a. Fst series humiditytemperature transmitters instruction manual. X intox ecir ii enhanced with serial number 10,000 or higher x. Alco sensor fst test equipment pdf manual download. View online operators manual for intoximeters alco sensor fst test equipment or simply click download button to examine the intoximeters alco sensor fst guidelines offline on your desktop or laptop computer. If the alco sensor fst indicates that you blew in the warn range, you will be subject to a 3, 7 or 30 day immediate roadside prohibition and vehicle seizure, along with fees payable to icbc. This is a preventable tragedy and the key to success is ensuring our response to impaired driving is swift, certain and significant. The instrument is easy to use and rugged enough to withstand vigorous field conditions and accurate enough to be considered an evidential testing device. Familiarize yourself with the operating instructions for the alcosensor fst by. When the display flashes acc, connect the mouthpiece of the fst to the mini alcohol can. Under normal operating conditions, little more than routine maintenance checks are all that is required to keep your alcosensor fst operational. Alcosensor iv with memory and slip printer for dot.

Asd approved screening device roadside breath tester. This video shows stepbystep instructions for performing a calibration adjustment on the alcosensor fst breath alcohol device. The sensors require recalibration or replacement every six months. Designed to be ergonomic and easytouse, yet jampacked with advanced features, the l series breathalyzers are stateoftheart tools that will protect roads, communities, and. In order for the device to accept a sample, the breath test subject must blow with a minimum flow rate, produce a minimum volume of breath, and blow over a minimum period of time. The alcosensor fst breathalyzer device is widely used by law enforcement, corrections and substance abuse treatment professionals worldwide. Dwi astds dwi attorney dwi lawyer dui attorneys dui. Alco sensor fst operator manual for british columbia users pdf, 745kb effective february 18, 2020. Following all calibration adjustments, a complete test will be performed according to steps 1 through 9. Intoximeter alcosensor fst breathalyser with printer. The manufacturer passes known bac levels through the sensor to set baseline values for testing. Alco sensor fst calibration adjustment instructions this video shows stepbystep instructions for performing a calibration adjustment on the alco sensor fst breath alcohol device. General information the alco sensor fst is a handheld breath alcoholtesting device designed to read bloodbreath alcohol concentrations. It also boosts rapid testing and has a wide operating temperature.

Lifeloc fc series has been trusted by organisations internationally. The alco sensor fst has been upgraded from the alco sensor ii by making it less prone to temperature recommended operational temperature between 32 and 122 degrees fahrenheit, reporting the reading much faster, and the ability to recall the last. To be able to use the warranty please strictly follow the manufacturers instructions concerning calibration of the breathalyser, which should be done every six months. Alcosensor fst possible results gottgetreu consulting ltd. The alco sensor iv is subject to temperature requirements of 50 degrees fahrenheit to 104 degrees fahrenheit. View online or download intoximeters alcosensor fst operators manual. Police officers are not able to submit evidence that a driver was impaired because they gave a specific reading on an alco sensor fst. Nov 22, 20 calibration checks were conducted on five alco sensor fsts over a period of seven weeks. This manual covers the operating information and procedures for the alco sensor fst.

This is up to a 16 hour course that includes physiology of alcohol, legal aspects. Long term stability of the humidity sensor is typically better than 1 %rh per year. The alco sensor fst is pocket sizes, evidential grade handheld breath alcohol tester which produces precise, accurate, and repeatable results on direct breath sample testing. It also offers a simple passive breath testing procedure for fast screening of multiple subjects, as well as the capacity to sniff alcohol in an open container by measuring the headspace over the liquid. Alcosensor fst dot evidential breathalyzer sgbreathalyzers. This training outline covers the approved draeger alcotest 9510 evidential breath test instrument and the alco sensor iii alco sensor fst pbt.

A disposable mouthpiece, two aa batteries, and a calibration standard are the only items necessary to keep the alcosensor fst operational. Iowa dci crime lab breath alcohol section iowa governors. Preliminary alcohol screening handheld pas dui lawyers report. When the alcosensor fst flashes cal, depress the valve on mini alcohol can for 4 seconds. The software presents simple to follow, stepbystep instructions which lead the operator through the instrument result download process. General information the alcosensor fst is a handheld breath alcoholtesting device designed to read bloodbreath alcohol concentrations. Download an illustrated copy of the calibration adjustment procedure. Unless your testing procedure dictates otherwise, a calibration is only necessary if an accuracy check has proven the instrument to be out of tolerance.

Calibration a the following breath alcohol screening test devices are approved as to type and make. The alco sensor fst is the industry standard for preliminary breath testing pbt instruments. Intoximeter alcosensor fst breathalyser innovative. Asds require a service check every year and a calibration check. Alco sensor iv dwf operator manual british columbia. Press the on button large button with triggerindex finger to power unit on. The alco sensor fst passive screener is a pocketsized, handheld. The alco sensor fst was approved for use as a screening device in 2012. Individual training allows the operator more freedom with.

Two aa batteries should run well in excess of tests. On the 3rd second of the 4second count, press the manual button. Calibration stability of the alcosensor fst over a seven. A series of tests was performed on two versions of the alco sensor iv. Alcosensor fst accuracy check procedure intoximeters. Alco sensor vxl breath alcohol tester intoximeters as a department, we are very pleased with the operation of alco sensor fst. This package bundles an alco sensor iv with memory with the portable dp1012 printer, an ideal choice of small footprint printer with lowvoltage operation for testing on the go. Alcosensor fst breathalyzer with mini alcohol gas can.

Intoximeter alcosensor fst breathalyser innovative testing. S creening devices give police a reliable method for determining a persons blood alcohol concentration. The alcosensor iv will sample the gas at this time. Attach mouthpiece e03 blank timeout 60 seconds insert closed end of mouthpiece into end of channel, single hole facing up. Oct 09, 2019 the alco sensor fst programmed for use in british columbia does not display a digital reading for any specific bloodalcohol content bac greater than 59 mg%.

Alcosensor calibration information instructional videos. New alco sensor ivs should be checked for accuracy once a week for the first month, and once a month thereafter. Preliminary alcohol screening handheld pas dui lawyers. Alcosensor fst approved screening device acumen law. Accuracy check and calibration procedure for the alcosensor. The alco sensor fst asfst provides precise, accurate, repeatable results on direct breath sample testing. Intoximeter alcosensor fst breathalyser with printer uk home office approved. Meet our newest and most advanced breath alcohol testers the l series. Department of transportation nhtsa special testing. Intoximeter alco sensor fst breathalyser with printer uk home office approved.